Domain 06b

Hyperconverged infrastructure

A hypervisor, distributed storage and one control plane on a cluster of servers: appliance, software and disaggregated models, cluster design, cluster networking, lifecycle, and built-in DR.

What it is

HCI runs a hypervisor, a distributed storage layer and one control plane on a cluster of servers, and each node contributes both compute and local drives. The storage network is the cluster’s east-west fabric: writes are replicated to other nodes, and a lost node or drive starts a rebuild that runs between many nodes at once (Nutanix Bible). Buyers choose HCI for faster time to VM, one operations plane and fewer separate SAN and array skills. The trade against 3-tier is coupled scale: compute and capacity grow together unless you use a disaggregated variant.

This page owns the HCI models, cluster design, HCI network decisions, lifecycle and HCI-native DR. Servers as hardware, NICs and host bonding are on Compute (Server networking). Storage architectures and storage protocols are on Storage (Storage networking). Oversubscription and ECMP are defined on Network: Fabric design, VLAN/VNI on Network: VNI/VRF design, and MTU on Network: MTU. Backup platforms, immutability and DR runbooks are on Backup.

Key tech subclasses

Appliance HCI

Vendor-built nodes sold with the HCI software as one product: a validated BOM, a factory image, and one support path for hardware and software. The vendor’s lifecycle tool updates firmware, drivers, hypervisor and storage software as a tested bundle. Examples: Dell VxRail (VMware vSAN), HPE SimpliVity, and OEM-branded Nutanix appliances. The trade is that you buy from the appliance’s node list and follow its release cadence.

Software HCI on certified nodes

The HCI software is licensed on its own and installed on servers from the vendor’s compatibility list. You get more hardware choice and own the match between firmware, drivers and the list (Compatibility lists). Examples: VMware vSAN under VCF or VVF, Nutanix AOS with AHV, and Microsoft Azure Local (Hyper-V and Storage Spaces Direct, managed through Azure Arc, on validated OEM machines) (Microsoft Learn).

Disaggregated HCI (dHCI)

A pattern, not one product: the HCI control plane and hypervisor lifecycle run on compute nodes, and data lives on external arrays or a separate storage cluster, so compute and capacity scale independently. Current examples: Nutanix compute clusters on external storage, where the CVM boots from a local boot device and manages no local data drives, reaching Dell PowerFlex through its SDC client and Everpure and Dell PowerStore over NVMe/TCP, with NetApp over NFSv3 announced (Nutanix Bible); Azure Local disaggregated deployments on SAN storage, generally available, 1 to 64 machines (Microsoft Learn); VCF with vSAN storage clusters or external arrays; and HPE Alletra dHCI and its successor path. Once storage is external, the storage network is a storage-protocol network: see Storage networking.

Cluster design, network, lifecycle and DR

Node count and resiliency, failure domains, stretched clusters and witnesses (Cluster design →); cluster traffic, RDMA and switch requirements (HCI network →); compatibility lists, updates and expansion (Lifecycle →); built-in replication and its limits (HCI DR →).

Design / build / manage

Design

  • Choose HCI, dHCI or 3-tier against scale ratio, failure domain, licensing basis and network demands (Choosing)
  • Set resiliency per cluster, then size node count for N+1 after resiliency overhead and rebuild headroom (Sizing)
  • Map the licensing basis (cores, and for some platforms raw capacity) before BOM lock; terms change often
  • Agree the HCI network decisions with the fabric team: NIC speed, RDMA or TCP, DCB, and rack and ToR placement (HCI network)
  • Pick the witness site for stretched and two-node designs and budget its link (Stretched clusters)

Build

  • Build to the vendor’s validated BOM and firmware and driver baseline (Compatibility lists)
  • Configure switch DCB, LLDP and VLANs where the platform requires them (Switch requirements)
  • Validate MTU end to end and RDMA under load before any workload moves (Network build)
  • Deploy the witness, then test node, rack and site loss
  • Decide how HCI snapshots and replication hand off to the backup platform (Backup)

Manage

  • Update through the vendor’s orchestrated path, one node at a time, with capacity headroom for resync (Updates)
  • Watch rebuild and resync times, free capacity, and noisy-neighbor contention
  • Watch PFC pause, ECN and RDMA error counters where RDMA is on
  • Monitor witness reachability; track node end of life and drive endurance
  • Rehearse node-loss and site-failover runbooks

Choosing HCI, dHCI or 3-tier

What each compute-platform model commits you to. Servers as hardware are on Compute; array and SAN design is on Storage. The rows are design judgment built on the sourced facts elsewhere on this page, except where a source is linked. Sources checked 6 Oct 2026.

CriterionHCI (appliance or software)dHCI3-tier (servers + array / SAN)
Scale unit A node adds compute and capacity together. A mismatched ratio strands one of them. Compute nodes and storage scale separately, under one HCI control plane Servers and arrays scale separately, under separate tools
Failure and admin domain Storage availability depends on the cluster’s own nodes; a node loss is also a storage rebuild Storage failure domain is the array or storage cluster; compute loss does not trigger a data rebuild Same as dHCI
Network demand Replication and rebuild traffic on the DC fabric, east-west. Some platforms require DCB, a dedicated ToR pair or same-rack placement (HCI network) A storage-protocol network to the arrays (Storage networking) FC SAN or IP storage (Storage networking)
Licensing basis Usually per core (Compute: Hypervisor licence metrics). vSAN is also licensed on raw TiB: VCF includes 1 TiB of vSAN per core, VVF 0.25 TiB (Broadcom KB 313548). Drive count per node can change the subscription. Azure Local is billed per physical core (Microsoft Learn). HCI software on compute nodes plus array software and support Hypervisor plus array software and support
Skills One platform team runs compute and storage Platform team plus array skills Separate server, SAN and array skills
Expansion Per node, within platform rules: switchless clusters may not grow in place, rack-aware clusters grow in pairs (Expansion) Per compute node or per array or shelf Per server or per array or shelf

Platform choice design / build / manage

Design

  • Profile the workload’s compute-to-capacity ratio and growth; a skewed ratio favors dHCI or 3-tier
  • Price licensing on the platform’s actual basis (cores, raw TiB), with a date on the quote
  • Check the network demands of the shortlisted platform with the fabric team before choosing

Build

  • Run a proof of concept on the target NICs and switches, including a node-loss rebuild

Manage

  • Re-test the choice at each refresh; licensing and roadmaps move faster than hardware cycles

Cluster design

Node count, resiliency settings, failure domains, and stretched clusters with their witnesses. Platform figures are from vendor documentation; where a figure was not confirmed it is left out and flagged. No VMs-per-node ratio is given: none was found in a primary source, so the page gives a method. Sources checked 5–6 Oct 2026.

Sizing method

  1. Take compute (vCPU, RAM) and usable capacity and performance from the workload inventory.
  2. Apply the resiliency overhead of the chosen setting to get raw capacity (Resiliency). A three-way mirror leaves about one third of raw capacity usable (Microsoft Learn).
  3. Keep free capacity to re-protect data after a node loss. Without it, a rebuild cannot complete and the cluster stays degraded.
  4. Size so the remaining nodes carry the load with one node in maintenance (N+1). Add a second spare node (N+2) when a failure during maintenance must be tolerated (Microsoft Learn).
  5. Split into clusters where it helps: management or infrastructure apart from workload, platform maximum cluster size, failure-domain size, and licensing boundaries.

Resiliency settings and node minimums

PlatformSettingNode minimum and behaviourSource
Nutanix AOS RF2 (tolerates one failure) or RF3 (two failures) RF2 needs at least 3 nodes. RF3 needs at least 5 nodes because metadata is then kept at RF5. Rebuild is spread across all CVMs, disks and uplinks, so it is many-to-many east-west traffic. Nutanix Bible
Azure Local Three-way mirror (and other volume resiliency types) Three-way mirror needs at least 3 machines and gives about 33% usable capacity. Losing 2 of 3 machines loses storage pool quorum. For two-failure tolerance Microsoft describes 4 machines plus a witness and N+2 compute. Microsoft Learn
VMware vSAN Storage policy (failures to tolerate, RAID-1/5/6); VCF 9.1 Auto-RAID In VCF 9.1, Auto-RAID sets the resilience policy from the cluster topology instead of a hand-set policy for most VMs. Per-RAID host minimums and maximum hosts per cluster are not given here. vSAN Stretched Cluster Guide (VCF 9.1)

Failure domains

Decide which physical unit the cluster must survive losing, then map it to power feeds and switches. A rack that is a failure domain needs its own feeds (Power) and its own ToR pair. Nutanix block awareness needs at least 3 blocks and rack awareness at least 3 racks (Nutanix Bible). Azure Local takes the opposite default: all machines in a site sit in one rack on one ToR pair, and a rack-aware cluster is the supported way to span two racks (Microsoft Learn, rack aware clustering). Site loss needs a stretched or metro design, below.

Stretched, metro and rack-aware clusters, and witness placement

A stretched cluster spans two sites with synchronous writes, and a witness at a third site breaks ties when the sites lose contact. Put the witness where it does not share a failure domain with either data site. The network rules for these links are in Inter-site and witness links.

vSAN stretched cluster (VCF 9.1)Nutanix Metro AvailabilityAzure Local rack-aware cluster
Between data sites At least 10 Gbps, at most 5 ms RTT Under 5 ms RTT At most 1 ms RTT between the two racks or rooms
Witness Third site, at most 200 ms RTT, about 2 Mbps per 1,000 components. Each stretched cluster needs its own witness, and a witness may not run on another stretched cluster that spans the same sites. Witness VM in a separate failure domain, managed from Prism Central; automates failover Cluster witness, per Microsoft quorum guidance
Scale Up to 20 + 20 + 1. VMware recommends 3 + 3 + 1 and does not encourage 2 + 2 + 1. Two separate clusters with containers replicated synchronously 2 + 2 up to 4 + 4. Not supported with external SAN storage.
Source vSAN Stretched Cluster Guide, 5 May 2026 Nutanix Bible · OVHcloud guide Microsoft Learn

Cluster design / build / manage

Design

  • Choose the resiliency setting first; it fixes the node minimum and the raw-to-usable ratio
  • Size for N+1 (or N+2) after resiliency overhead, with free capacity for a full rebuild
  • Map node, block, rack and site failure domains to power feeds and ToR pairs
  • Place the witness at a third site that shares no failure domain with either data site

Build

  • Confirm the platform reports the intended fault domains before loading data
  • Fail a node, a rack (where designed for) and the inter-site link, and time the rebuild

Manage

  • Re-check usable capacity against the rebuild reserve after every expansion
  • Alert on any period of reduced redundancy, not only on outages

HCI network decisions

What the HCI platform demands of the network: traffic classes, host NIC speed, fit to the fabric, RDMA, switch requirements, switchless designs, and inter-site links. Shared definitions are not restated here: oversubscription is on Network: Fabric design, MTU and overlay overhead on Network: MTU, lossless Ethernet on Network: Lossless Ethernet, firewall insertion on Network: Service insertion, and the management network on Network: OOB. NIC hardware and host bonding are on Compute: Server networking. External-array protocols for dHCI are on Storage networking. Platform rules differ sharply, so they are compared rather than generalized. Sources checked 5–6 Oct 2026.

Cluster traffic classes

TrafficPatternNotes
Storage replication Every write is copied to one or more other nodes before it is acknowledged. East-west and latency-sensitive. Nutanix keeps reads local to the VM’s node where it can, so the network mostly carries replica writes, rebuilds and remote replication (Nutanix Bible). On Azure Local, storage traffic is SMB (Storage Spaces Direct), which Microsoft classes as Layer 2 and not routable (Microsoft Learn).
Rebuild and resync Many-to-many bursts after a drive or node loss, and after maintenance This is the load that exposes oversubscription and the ToR pair’s peer link. Size for it, not for steady state.
Live migration Bursty memory copy between hosts On Azure Local it runs over SMB and can use RDMA. Microsoft’s guidance is RDMA when at least 5 Gbps is available to it, compression below that (Microsoft Learn).
Cluster heartbeat and management Small but must never be starved Azure Local reserves a system class for heartbeats: 2% on 10 GbE or slower RDMA networks, 1% on 25 GbE or faster. BMCs belong on OOB.
VM traffic North-south and east-west The default class; shares uplinks with storage on converged designs
Remote replication and witness Leaves the site over L3 See Inter-site and witness links and Backup: Replication bandwidth for bandwidth from RPO

Host NIC speed and count

  • vSAN ESA. VMware’s ReadyNode profiles run from 10 Gbps for the smallest (AF-0) through 25 Gbps (AF-2 to AF-6) to 100 Gbps (AF-8), and VMware calls 25 Gbps the practical minimum for new environments (VMware, Oct 2022).
  • Azure Local. Each NIC must carry a Windows Server Catalog qualification for the traffic it carries (Management; Compute Standard or Premium; Storage Standard or Premium), and using an adapter outside its qualified type is not supported. Inbox drivers are not supported. Teaming is Switch Embedded Teaming only: switch-independent, up to eight identical adapters, no LBFO (Microsoft Learn). Microsoft’s converged example on 2 × 25 GbE reserves half the team for SMB, splitting it 70% storage, 29% live migration and 1% heartbeat. Microsoft labels this an example, not a support requirement.
  • Nutanix. No primary NIC-speed guidance was fetched this pass.
  • Dedicated or converged ports. VMware recommends dedicated ports for RDMA rather than mixing RDMA and TCP on one uplink (VMware, Jun 2025). Count ports per node for storage, VM and management, then match ToR port count to the cluster’s growth.
  • No host LAG on RDMA storage ports. vSAN RDMA does not support LAG/LACP (Broadcom KB 382163), and Azure Local SET is switch-independent. The leaves can still be an MLAG or EVPN multihoming pair (Network: Multihoming), but the RDMA storage ports are single-homed, one per leaf, not bundled. Bonding mechanics: Compute: Server networking.

Fit to the fabric

The ratio math is on Network: Fabric design. VMware says that aiming for 1:1 oversubscription in a spine-leaf network gives vSAN the most consistent performance (VMware, May 2025). Microsoft asks you to minimize or preferably eliminate oversubscription (Microsoft Learn). The constraints below are specific to HCI platforms.

  • Same rack, same ToR pair (Azure Local). All machines in a site must be in the same rack and on the same ToR switches (Microsoft Learn). This fixes rack and leaf planning (Racks): reserve the rack, power and ToR ports for the cluster’s full size.
  • One subnet and VLAN per storage NIC side (Azure Local). With both storage ports on one subnet, SMB Multichannel opens cross connections that congest the MC-LAG peer link. Microsoft recommends a separate subnet and VLAN per side so left-side traffic stays on ToR 1 and right-side on ToR 2 (Microsoft Learn).
  • Storage traffic stays in Layer 2. Azure Local storage is not routable (Microsoft Learn). Broadcom says not to run vSAN RoCE over Layer 3 or use LAG/LACP with RDMA (Broadcom KB 382163), so the vSAN RDMA interfaces share one L2 segment. An L2 VNI stretched across leaves is still L2, so this is a design choice, not a rule: spanning racks means carrying lossless Ethernet over VXLAN, which is platform-dependent (Network: Lossless Ethernet), while confining the RDMA cluster to one leaf pair is simpler and is the recommended design. vSAN over TCP has no such constraint.
  • Same active uplink on every host. Set an explicit failover order so every host uses the same active storage uplink. Storage then stays on one leaf and off the peer link.
  • Consistent L2 settings (vSAN). Every vSAN interface in a cluster uses the same VLAN, MTU and subnet; verify with vmkping at the configured MTU (Broadcom techdocs).
  • MTU. Set the storage interface MTU end to end and prove it with DF-set pings at that size. Overlay overhead and underlay MTU are on Network: MTU. Azure Local SDN compute needs a switch MTU between 1514 and 9174 (Microsoft Learn).
  • Buffers (vSAN). VMware looks for at least 1 MB of buffer per port on switches without VoQ, and notes buffers do not make up for link speed (VMware, Oct 2022).
  • Hop count (Nutanix). Nutanix guidance is reported as leaf-spine with no more than three switches between nodes in a cluster.

RDMA for HCI

RDMA cuts host CPU and latency for storage traffic, but RoCE puts lossless-Ethernet configuration on every switch port in the path. Decide per platform, and only where the network team will run DCB. PFC, ETS, ECN and DCQCN mechanics, and the PFC watchdog, are explained on Network: Lossless Ethernet.

PlatformTransportFabric requirementKey limitsSource
VMware vSAN RoCE v2 DCB and PFC on the switches for the vSAN traffic; Layer 2 only VMware advises RDMA only with ESA. Up to 32 hosts. Not with 2-node clusters, stretched clusters, datastore sharing or vSAN storage clusters. Teaming: originating virtual port or source MAC hash only, no LACP or IP hash. Do not mix NIC vendors in a cluster. In VCF 5.2, SDDC Manager workflows did not support vSAN RDMA. VMware, Jun 2025 · Broadcom KB 382163
Azure Local iWARP or RoCE; InfiniBand not supported DCB required for RoCE, optional for iWARP. RoCE needs three traffic classes across hosts and fabric: system (priority 7, no PFC), RDMA (priority 3 or 4, PFC on, about 50%), and default. Switched deployments need Microsoft’s ToR QoS policy for both RoCE and iWARP. Adapters must match protocol (iWARP to iWARP, RoCE to RoCE). Microsoft suggests iWARP if you do not manage the ToR switches. SET teaming only. Host network · Physical network
Nutanix AOS RoCE, via the CVM DCB and PFC on the switches for older NICs; Nutanix describes a mode on newer NICs and AOS releases that avoids switch DCB configuration Reported: no NIC failover for RDMA, one RDMA port, no mixed adapter models. Nutanix Bible

Vendor switch requirements

PlatformSwitch listMandatory features
Azure Local Microsoft does not certify switches. It publishes a vendor-confirmed list per release and per role (management, storage, compute standard, compute SDN), with a minimum switch OS version. Some listed models are confirmed for management and compute but not storage. The list changes as vendors report. All roles: IEEE 802.1Q VLANs and 802.1AB LLDP with required TLVs. Storage role: 802.1Qbb PFC and 802.1Qaz ETS, at least three CoS priorities with one lossless, and LLDP TLVs for VLAN name (at least 10 VLANs), link aggregation, ETS configuration and recommendation, PFC configuration and maximum frame size. Ingress QoS rates unset or equal to the ETS egress rates. Management role: DHCP relay. SDN compute role: BGP and MTU 1514 to 9174. Microsoft does not test with DSCP.
VMware vSAN No switch list Consistent VLAN, MTU and subnet on all vSAN interfaces. For RDMA, PFC on the vSAN traffic class; Broadcom states the switch configuration must be validated with the switch vendor.
Nutanix Not confirmed from a primary source this pass.

Sources: Azure Local physical network requirements (ms.date 27 Mar 2026); vSAN network checklist; Broadcom KB 382163. Check the switch OS version against the platform release before every switch or cluster upgrade.

Switchless (direct-connect) small clusters

Azure Local can run storage over direct full-mesh links between machines, with redundant links per pair. ToR switches are still needed for management and VM traffic. Direct links remove the switch QoS, PFC and ECN configuration, but Network ATC still configures the host storage intent, and the RDMA protocol, adapters and firmware must match the validated pattern. Host-side DCB still applies to RoCE on the direct links; only the switch policy drops out. Storage-switchless supports at most 4 machines, and Microsoft recommends 3 for production. The benefit falls off above 3 because of NIC count, and adding a machine means moving to switched storage or redeploying (Microsoft Learn, physical network). vSAN also has a 2-node direct-connect design. Choose switchless only for clusters that will not grow.

Inter-site and witness links

Latency, bandwidth and witness budgets per platform are in the stretched cluster table. The overlay between sites is designed on Network: Multi-site and the DCI circuits on Network: DCI.

  • vSAN witness traffic is routed (Layer 3) from each data site to the witness, even when the two data sites share Layer 2 (vSAN Stretched Cluster Guide).
  • With witness traffic separation, the witness path can use a different MTU from the inter-site link, for example 9000 between data sites and 1500 to the witness (same source). The 9000-byte data MTU must still fit the DCI after overlay and encryption overhead (Network: MTU).
  • Keep firewalls, NAT, IDS/IPS and WAN optimizers out of the vSAN VMkernel path (same source). Carry this traffic in a VRF with no firewall in the path, and record it as L3/L4-only in the inter-zone matrix of the segmentation policy model.
  • Size asynchronous replication links from RPO and change rate on Backup: Replication bandwidth.

HCI network design / build / manage

Design

  • Decide RDMA or TCP per platform, and whether the network team will run DCB on the storage ToR ports
  • Pick NIC speed and count against the platform minimum and rebuild traffic, not steady-state load
  • Place each cluster per the platform’s rack and ToR rules, and reserve ports for its full size
  • Give each storage NIC side its own subnet and VLAN where the platform recommends it
  • Record the DCB priorities and ETS shares with the fabric team so hosts and switches match
  • Budget inter-site and witness links before choosing a stretched design

Build

  • Apply the platform’s switch reference configuration (PFC, ETS, LLDP TLVs, VLANs) to storage ToR ports
  • Prove MTU end to end with DF-set pings at the configured size on every storage path
  • Confirm RDMA is actually in use under load (host and switch counters), not only that pings pass
  • Pull a link and a node under load; watch resync and confirm storage traffic stays off the ToR peer link

Manage

  • Watch PFC pause frames, PFC watchdog events, ECN marks and RDMA retransmits
  • Check the switch OS against the platform’s list before switch upgrades
  • Re-validate RDMA and MTU after NIC firmware or driver updates
  • Trend ToR uplink use during resync and maintenance windows

Lifecycle

Compatibility lists, orchestrated updates and expansion rules. Release cadences and supported node generations change often; recheck at every revision. Sources checked 5–6 Oct 2026.

Compatibility lists

PlatformListNotes
VMware vSAN Broadcom Compatibility Guide, vSAN ESA ReadyNodes Node profiles set minimum NIC speed (Host NICs)
Azure Local Azure Local catalog for machines; Windows Server Catalog role qualifications for NICs Adapters outside their qualified traffic type and inbox drivers are not supported (Microsoft Learn)
Nutanix Hardware compatibility list and compatibility matrix Published on the Nutanix portal
Appliances The appliance vendor’s node list per release Each release supports a range of node generations, sometimes with limits on the newest (for example, greenfield or non-stretched only).

Orchestrated updates

HCI platforms update the full stack (BMC and drive firmware, NIC drivers, hypervisor, storage software) against a validated bundle, rolling one node at a time while data is evacuated or resynced. Examples are vSphere Lifecycle Manager, Nutanix LCM, Azure Local solution updates and VxRail Manager. Each node out of service is a capacity and redundancy reduction, so updates need the same headroom as a node loss. vSAN can upgrade the witness appliance in the same vLCM workflow as the cluster (vSAN Stretched Cluster Guide). Azure Local documentation is versioned by monthly release (for example 2603 to 2610), so check requirements against the release you run (Microsoft Learn).

Expansion

  • Expand by node within the platform’s list and generation rules; mixed generations may be limited
  • Where capacity is licensed on raw TiB, adding drives changes the subscription (Licensing basis)
  • Azure Local switchless clusters cannot add a machine in place; rack-aware clusters grow in pairs, 2 + 2 to 3 + 3 to 4 + 4 (switchless, rack aware)
  • Under a same-rack rule, the rack, power and ToR ports for growth must be reserved at day one

Lifecycle design / build / manage

Design

  • Pick nodes and NICs from the current list, and check how long that generation stays supported
  • Plan expansion steps and the rack, power and switch ports they need

Build

  • Bring every node to the same validated bundle before the cluster is created

Manage

  • Patch on a controlled cadence through the orchestrated path, never node by node by hand
  • Track node end of life, drive endurance and the list status of each component

HCI DR: built-in replication

What the HCI platform provides natively, and where it stops. Backup platforms, immutability, DR runbooks and replication bandwidth sizing are on Backup. Sources checked 5 Oct 2026.

Replication options

MechanismRPO classPlatform examples
Synchronous (stretched or metro) Zero vSAN stretched cluster; Nutanix Metro Availability (Stretched clusters)
Near-synchronous Low minutes or less Nutanix NearSync, under protection policies and recovery plans (Nutanix Bible)
Asynchronous snapshots Snapshot interval Nutanix async protection policies; Azure Local through Azure Site Recovery, Azure Backup or partner products (Microsoft Learn); vSAN through add-on replication

Replication is not backup

Snapshots and replication share the cluster’s failure and admin domain. Corruption, ransomware or a bad admin action replicates as faithfully as good data, and an attacker with cluster admin rights can delete both copies. Keep backup to an independent, immutable target as well (Backup). Map each workload’s RPO and RTO to a mechanism: synchronous for zero RPO within metro distance, asynchronous for the rest, and backup for recovery from logical damage.

HCI DR design / build / manage

Design

  • Assign each workload tier a mechanism from its RPO and RTO; leave link sizing to Backup
  • Keep backup admin identities and targets outside the HCI admin domain (Identity)

Build

  • Hand HCI snapshots and replication off to the backup platform; test a restore, not only a failover

Manage

  • Alert on replication lag against RPO; rehearse failover and failback on a schedule

Products in HCI

4 catalog lines · grouped by category, then vendor · click a product for details
Full catalog →

Market leaders & comparison

Closest public Gartner lens is the Magic Quadrant for Distributed Hybrid Infrastructure (DHI): hybrid and HCI-style platforms, not a bare-metal server MQ. The 2026 edition is dated 7 Sep 2026, and Nutanix states it is a Leader (Nutanix PR, 10 Sep 2026). Other 2026 positions were not confirmed from a public vendor source this pass, so other badges show the 2025 edition (8 Sep 2025), whose public coverage named AWS, Microsoft, Broadcom (VMware), Oracle and Nutanix as Leaders (Virtualization Review; VMware PR). Cloudbit’s on-prem HCI shortlist below adds Dell VxRail and HPE HCI lines as widely sold appliance and dHCI lines, not as invented DHI MQ positions. No scores or ranks invented. Licensing terms and roadmaps in this table change often; dated 6 Oct 2026.

Vendor / productStrengthsTypical fitCaveatsSources
Nutanix AHV / NCI DHI MQ Leader 2026 Unified SDS + AHV (or other hypervisors); consistent hybrid ops; frequent VMware-alternative shortlist On-prem HCI / private cloud when buyer wants software-defined cluster ops on OEM nodes Trade coverage notes perception as expensive vs hyperscalers; on-prem deals are quote-driven Nutanix PR Sep 2026 · Sep 2025
Broadcom (VMware) vSAN / VCF DHI MQ Leader 2025 Mature VCF stack (vSphere + vSAN + NSX path); deep ecosystem and admin skill base VMware-centric estates staying on Cloud Foundation / vSAN HCI Cores licensed with a 16-core-per-CPU minimum and vSAN on raw TiB (Licensing basis); support and licensing sentiment under Broadcom: probe TCO and alternatives explicitly VMware PR Sep 2025
Microsoft Azure Local DHI MQ Leader 2025 (Microsoft) Hyper-V and Storage Spaces Direct on validated OEM machines, managed through Azure Arc; the most prescriptive published NIC and switch requirements of the platforms here (Switch requirements); disaggregated SAN option Microsoft-centric estates wanting Azure-managed on-prem clusters Billed per physical core; needs outbound connectivity to Azure at least every 30 days; all machines in a site on one rack and ToR pair Microsoft Learn · Physical network
Dell VxRail Appliance HCI Validated PowerEdge-based HCI appliance; tight VMware integration historically; Dell lifecycle tooling Dell-standardized DCs wanting turnkey VMware HCI nodes Confirm current SKU / Dell Private Cloud path on quote (portfolio in transition in trade press) Dell VxRail public product materials; CRN trade coverage on Dell HCI roadmap
HPE SimpliVity / Alletra dHCI Public HCI line SimpliVity for edge/general VM HCI; Alletra dHCI for independent compute/storage scale; GreenLake adjacency HPE-standardized estates, edge HCI, or dHCI when SDS ratio flexibility matters Two architectures under one “HCI” umbrella, so pick SimpliVity or dHCI deliberately. Confirm on quote whether Alletra dHCI or Private Cloud Business Edition with Alletra Storage MP is the current orderable dHCI path. HPE Alletra dHCI; HPE SimpliVity store/product pages

Dell VxRail — within-vendor node ladder (15G nodes, example)

Dell VxRail P670F, P670N, V670F, and S670 installation and service manual, system overview, fetched 3 Oct 2026. All four are 2U and are 3rd Gen Xeon / DDR4 (15G-era) nodes; current VxRail releases also support later generations, which are not listed here. HPE SimpliVity / Alletra dHCI chassis heights were not on a page fetched this pass, so they are not given SKU rows. No list prices. No estimated watts from this manual.

NodeRUWhat the manual states
P670F2U Up to two 3rd Gen Intel Xeon Scalable. 16 DDR4 DIMMs single-socket, 32 dual-socket. Single-socket: up to 24× 2.5 in SAS/SATA front, four universal NVMe slots, no rear drives. Dual-socket: those front drives plus 4× 2.5 in rear.
P670N2U Dual-socket, 32 DDR4 DIMMs, up to 24× 2.5 in all-NVMe front. Do not mix drive capacities. vSAN ESA: minimum 128 GB RAM, 2–24 drives, minimum 16 cores per processor.
V670F2U Dual-socket, 32 DDR4 DIMMs, up to 24× 2.5 in SAS/SATA front with four universal NVMe slots.
S6702U Up to two 3rd Gen Xeon Scalable, 32 DDR4 DIMMs, up to 12× 3.5 in SAS/SATA front plus 4× 2.5 in SAS/SATA/NVMe rear.

Source: P670 / V670 / S670 system overview. E660 / E660F / E660N technical-specifications page did not render chassis dimensions, so those models are omitted. Catalog VxRail line is 2U and Configure offers these four classes.

Nutanix NX — name ladder, not a public spec ladder

Corrects the prior table. The specsheet widget rendered only as “Loading…” and was not usable. Public pages do not state RU, CPU family, drive counts, or GPU counts. Those cells are “not stated on public page,” not filled from the regulatory-model string (that encoding is not defined in Nutanix’s letter) and not filled from reseller listings. A previous pass that showed 1U1N / 2U1N / Xeon generation / core / TB figures for NX is withdrawn.

Series blurbs, from the fetched NX Platforms page only:

SeriesWhat the page saysRUCPU familyDrives / GPU count
1000 Entry. not stated on public page not stated on public page not stated on public page
3000 Balance of compute and storage. Page text also names virtualization, private cloud, VDI, and workloads that require GPUs. No per-SKU GPU count. not stated on public page not stated on public page GPU count: not stated on public page
8000 High-performance. The page says single-node platforms for high-density compute and storage, business-critical apps, databases, big data, AI/ML. That is a series sentence, not a per-SKU RU. not stated on public page not stated on public page not stated on public page
9000 GPU-accelerated systems for AI. not stated on public page not stated on public page GPU count and GPU model: not stated on public page

Models named on that page: NX-1150S (“single socket NX-1150S” — family and core count are not stated) and NX-1175S (named next to it; the words “single socket” attach to the NX-1150S, not clearly to the NX-1175S). Generation, RU, and drive counts are not on the page. Orderable G9 SKUs are the pattern NX-…-G9-xxxxY (x = 0–9) from Nutanix’s own G9 regulatory vs SKU statement, 17 Feb 2025. The letter does not define the regulatory-model string, so those strings are not decoded into RU or node count. CE declarations fetched from nutanix.com call the product a “Converged Server/Storage System” and do not state CPU, drives, GPU, RU, or node count.

Orderable patternWhat Nutanix statesRUCPUDrives / GPU
NX-1150S-G9-xxxxY 1000 series, entry. nx-platforms: “single socket NX-1150S”. not stated on public page Single socket. Family, core count: not stated on public page not stated on public page
NX-1175S-G9-xxxxY 1000 series, entry. Named on the series page. Single-socket wording is not clearly this model. not stated on public page not stated on public page not stated on public page
NX-1165-G9-xxxxY 1000 series, entry (series page only; this SKU is not named there). not stated on public page not stated on public page not stated on public page
NX-1265-G9-xxxxY Series role not stated per SKU. Same regulatory model as NX-1165-G9 and NX-1365-G9 (not decoded). not stated on public page not stated on public page not stated on public page
NX-1365-G9-xxxxY Same regulatory model as NX-1165 / NX-1265. Series role not stated per SKU. not stated on public page not stated on public page not stated on public page
NX-3135-G9-xxxxY 3000 series blurb only. No per-SKU GPU count. not stated on public page not stated on public page not stated on public page
NX-3155-G9-xxxxY 3000 series blurb. Shares a regulatory model with NX-8155-G9 (not decoded). not stated on public page not stated on public page not stated on public page
NX-3235-G9-xxxxY 3000 series blurb. Shares a regulatory model with NX-3135-G9 (not decoded). not stated on public page not stated on public page not stated on public page
NX-3260-G9-xxxxY 3000 series blurb only. Shares a regulatory model with NX-3160-G9 and NX-3360-G9 (not decoded). not stated on public page not stated on public page not stated on public page
NX-3160-G9-xxxxY Same regulatory model as NX-3260 / NX-3360. Series role not stated on the letter beyond that pairing. not stated on public page not stated on public page not stated on public page
NX-3360-G9-xxxxY Same regulatory model as NX-3160 / NX-3260. not stated on public page not stated on public page not stated on public page
NX-8150-G9-xxxxY 8000 series blurb (single-node is that series sentence, not repeated on the SKU letter). not stated on public page not stated on public page not stated on public page
NX-8155-G9-xxxxY 8000 series blurb. Shares a regulatory model with NX-3155-G9 (not decoded). not stated on public page not stated on public page not stated on public page
NX-8155A-G9-xxxxY 8000 series blurb only. not stated on public page not stated on public page not stated on public page
NX-8170-G9-xxxxY 8000 series blurb only. not stated on public page not stated on public page not stated on public page
NX-9151-G9-xxxxY 9000 series blurb: GPU-accelerated systems for AI. No GPU count or GPU model on the page or the declaration. not stated on public page not stated on public page GPU count and GPU model: not stated on public page

NX-3060-G9 is not on this ladder. A file named nx-3060-G9-doc.pdf returns HTTP 200 but the scanned page is a CE declaration for a regulatory model the 17 Feb 2025 letter assigns to NX-3160-G9, NX-3260-G9, and NX-3360-G9. It does not name NX-3060. G10 names and any 1U/2U/4U reading of a model string are omitted. OEM appliance model numbers (Dell XC, HPE DX, Lenovo HX, Cisco, Fujitsu) were not listed. Catalog line does not claim a rack height or a CPU class. The previous 2100 W planning figure was not from a public page and is removed.

MQ is opinion research, not an ordered ranking; Gartner does not endorse vendors. DHI Leadership is not a rack-server ranking. Example Rival Snapshot for HCI can be added later under examples/.

Sources

Sources for the design sections above. Market-table and node-ladder sources are cited in place. Vendor documentation is primary for that vendor’s own platform. Research notes with per-claim detail are kept with the site source.

SourceTypeUsed forChecked
Azure Local host network requirements (ms.date 15 Jan 2026)Primary (vendor docs)Traffic types, NIC roles, SET, RDMA classes, bandwidth example, guest RDMA6 Oct 2026
Azure Local physical network requirements (ms.date 27 Mar 2026)Primary (vendor docs)Switch roles and IEEE/LLDP requirements, same-rack rule, oversubscription, switchless6 Oct 2026
Azure Local storage switchless reference architecture (ms.date 28 Sep 2026)Primary (vendor docs)Switchless limits, mirror capacity, N+1/N+25 Oct 2026
Azure Local rack aware clustering overviewPrimary (vendor docs)Rack-aware latency, scale, SAN exclusion5 Oct 2026
Azure Local disaggregated deployments (ms.date 13 Jul 2026)Primary (vendor docs)dHCI, billing basis, Azure connectivity, DR options5 Oct 2026
vSAN Stretched Cluster Guide, VCF 9.1 (5 May 2026)Primary (vendor docs)Stretched limits, witness, Auto-RAID, vLCM witness upgrade5 Oct 2026
VMware: vSAN networking, is RDMA right for you? (Jun 2025)Vendor blogvSAN RDMA limits, teaming, dedicated ports, VCF 5.26 Oct 2026
Broadcom KB 382163: configuring RDMA for vSANPrimary (vendor KB)PFC, no RoCE over L3, no LAG, no mixed NIC vendors6 Oct 2026
Broadcom KB 313548: VCF/VVF licensingPrimary (vendor KB)Core minimum, vSAN raw TiB entitlement5 Oct 2026
VMware: designing vSAN networks, 2022 (ESA)Vendor blogReadyNode NIC speeds, switch buffers5 Oct 2026
Broadcom techdocs: vSAN network checklistPrimary (vendor docs)VLAN/MTU/subnet consistency, vmkping5 Oct 2026
VMware: vSAN network oversubscription (May 2025)Vendor blog1:1 guidance (quoted on Network)5 Oct 2026
Nutanix Bible: data resilience and HAVendor (community-maintained by Nutanix staff)RF minimums, block and rack awareness, rebuild5 Oct 2026
Nutanix Bible: AOS architectureVendorData locality5 Oct 2026
Nutanix Bible: data I/O pathVendorRoCE mechanism5 Oct 2026
Nutanix Bible: backup and DRVendorMetro Availability5 Oct 2026
Nutanix Bible: DR servicesVendorAsync, NearSync, protection policies5 Oct 2026
Nutanix Bible: external storageVendordHCI pattern and targets5 Oct 2026
OVHcloud: Nutanix Metro AvailabilitySecondary (operator guide)Metro RTT figure5 Oct 2026